Applications (examples): Klystron; Pulsed Electric Field (PEF), RF power systems; ion implantation, Non Destructive Testing (NDT) systems, X-Ray power supplies systems, Cyclotron.
Download Data Sheet Request a quote
With more than 10 years of experience in design and production of electron beam welding, TECHNIX offers a complete range of sources dedicated for this application.
Based on double-resonance technology, these power supplies offer many advantages in terms of performance, flexibility, reliability and price.
Separate models are offered for customers who have their own oil tank and looking for the most economical solution.
HV block and regulation block are delivered separately.
HV block is immerged in customer oil tank and the connection between HV and regulation can easily be made.
In standard 45 kV, and 60kV are available. Other Voltages can be considered.
Power range from 6 kW to 120 kW.
Mains voltage
3 x 400V ± 10% 50-60Hz + Earth
Other values can be considered
Polarity:
Negative (Earth reference)
Voltage regulation
Load variation: better than ± 0.1 % of full voltage (for 10 to 100 % load)
Line regulation: better than ± 0.05 % of full load (for a ± 10% variation of mains voltage)
Current regulation
Load variation: better than ± 0.5 % of full voltage (for 10 to 100 % load)
Line regulation: better than ± 0.05 % of full load (for a ± 10% variation of mains voltage)
Ripple + Noise: less than 0.1% RMS of full voltage
Stored energy: 1 J/ kW
Stability (after one hour warm-up)
0.1 % after 8 hours of operating with constant load and ambient temperature
Temperature coefficient: 200 ppm/°C
Operating temperature: from 0 to 40°C
Stocking temperature: -20 to + 60°C
CE Certification
Adjustable output voltage | Adjustable output current | Efficiency | Stored energy | Dimensions of HV block | Size with separated block | Weight | |
6 kW | 0 to 60 kV | 0 to 110 mA | > 90% | < 6 Joules | H265xW454xD340 mm | 3U 19" rack | 50 kg |
15 kW | 0 to 60 kV | 0 to 260 mA | > 90% | < 15 Joules | H265xW454xD340 mm | 5U 19" rack | 70 kg |
20 kW | 0 to 60 kV | 0 to 340 mA | > 92% | < 20 Joules | H265xW454xD340 mm | 5U 19" rack | 75 kg |
40 kW | 0 to 60 kV | 0 to 680 mA | > 92% | < 40 Joules | H530xW454xD340 mm | 18U 19" cabinet | 200 kg |
60 kW | 0 to 60 kV | 0 to 1.05 A | > 92% | < 60 Joules | H530xW454xD680 mm | 24U 19" cabinet | 280 kg |
80 kW | 0 to 60 kV | 0 to 1.34 A | > 92% | < 80 Joules | H530xW454xD680 mm | 36U 19" cabinet | 350 kg |
6 kW | 15 and 20 kW | 40 kW | 60 kW | 80 kW |
![]() |
![]() |
![]() |
![]() |
![]() |
P1: Adjustment of Trs: High Voltage Raising Time when starting.
Min and max times are customer defined. Typically adjustable from 0.2 to 2s.
P2: Adjustment of Tstop: HV stop time following an electric arc.
Min and max times are customer defined. Typically adjustable from 2 to 100ms.
P3: Adjustment of Tra: HV Raising time following a stop due to an electrical arc.
Min and max times are customer defined. Typically adjustable from 5 to 125ms.
2018 © Technix. ALL Rights Reserved. Privacy Policy | Terms of Service