Format:
3U 19” Rack, 480mm depth (600mm depth over 100kV)
Efficiency:
> 90% at full load
Mains input:
170 V to 255VAC, 47-63 Hz
Single Phase + Earth
Input Power Factor:
≥ 0.98 at full load
Inrush current:
Limited to operating current at full power
Local controls:
Mains power switch, safety lock, HV on, HV off, Over current mode, Preset, Voltage an current setting, Limitation of voltage setting.
Status Indicators:
HV on, HV off, Line, Fault, Interlock, Remote, Over current limitation/protection, Regulation mode
Voltage and current display:
4.5 Digit
Output voltage and current setting:
Continuously adjustable from 0 to 100%
Local control mode:
10 turn potentiometer (0.05% resolution)
Remote control mode:
External 0 to 10V signal
Voltage and current regulation*:
Static Load regulation:
±0.05% of full voltage or current for no load to full load variation – better on demand
Static Line regulation:
±0.05% of full voltage or current for ±10% mains voltage variation (better on demand)
Stability (after 1-hour warm-up):
100 ppm /hour, operating at constant load and temperature
Regulation modes:
Constant Voltage (CV) and Constant Current (CC) regulations, with automatic crossover.
Power regulation on demand.
Protections:
Short circuit, Arc quench, External interlock, Over temperature, Overload, Over voltage, Over current,
Cooling:
Air forced
Air inlet on the front panel, with dust filters
Air outlet on the rear panel
Ambient temperature:
From 0 to 50 °C
Ambient Humidity:
0 to 80% at 25°C, 50% at 40°C (non-condensing)
Temperature coefficient:
100 ppm/°C
Documentation:
User manual, Test report, EU declaration of conformity (CE), RoHS2 declaration of conformity
Accessories:
Removable 3m coaxial HV cable with one plug mounted on one end.
Interlock connector.
2 keys for safety lock.
CE22 power cord for mains connection (for 300W, 600W and 1200W models).
CE19 power cord for mains connection (for 2000W models).
Standards and regulations:
Low voltage directive: 2014/35/EU
EMC directive: 2014/30/EU
RoHS directive: 2011/65/EU
EN 61000-6-2:2005 + AC (2005)
EN 61000-6-4:2007 + A1 (2011)
EN 61326-1:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61010-1:2010