HV DC power supply

SR up to 150kV Power up to 2kW

Rack mounted power supply, voltage up to 150kV and power up to 2kW, for single phase mains.

Main specification

Charging Power:

300W, 600W, 1200W and 2000W

Voltage:

up to 150kV

Polarity:

Positive, Negative, Reversible

Rise time (10-90%):

< 300ms - better on demand

Ripple + Noise :

0.1% RMS of full voltage - better on demand

Remote interface:

0-10V analogue – see other interfaces

Based on the ZCS resonant topology, the SR series is a multipurpose range designed to offer the best performance in a compact design.

Dry isolated, it offers high reliability and high operational availability. No special maintenance is required.

Detailed specification

Format:
3U 19” Rack, 480mm depth (600mm depth over 100kV)
Efficiency:
> 90% at full load
Mains input:
170 V to 255VAC, 47-63 Hz
Single Phase + Earth
Input Power Factor:
≥ 0.98 at full load
Inrush current:
Limited to operating current at full power
Local controls:
Mains power switch, safety lock, HV on, HV off, Over current mode, Preset, Voltage an current setting, Limitation of voltage setting.
Status Indicators:
HV on, HV off, Line, Fault, Interlock, Remote, Over current limitation/protection, Regulation mode
Voltage and current display:
4.5 Digit
Output voltage and current setting:
Continuously adjustable from 0 to 100%
Local control mode:
10 turn potentiometer (0.05% resolution)
Remote control mode:
External 0 to 10V signal
Voltage and current regulation*:
Static Load regulation:
±0.05% of full voltage or current for no load to full load variation – better on demand
Static Line regulation:
±0.05% of full voltage or current for ±10% mains voltage variation (better on demand)
Stability (after 1-hour warm-up):
100 ppm /hour, operating at constant load and temperature
Regulation modes:
Constant Voltage (CV) and Constant Current (CC) regulations, with automatic crossover.
Power regulation on demand.
Protections:
Short circuit, Arc quench, External interlock, Over temperature, Overload, Over voltage, Over current,
Cooling:
Air forced
Air inlet on the front panel, with dust filters
Air outlet on the rear panel
Ambient temperature:
From 0 to 50 °C
Ambient Humidity:
0 to 80% at 25°C, 50% at 40°C (non-condensing)
Temperature coefficient:
100 ppm/°C
Stored Energy:
1J/kW
Documentation:
User manual, Test report, EU declaration of conformity (CE), RoHS2 declaration of conformity
Accessories:
Removable 3m coaxial HV cable with one plug mounted on one end.
Interlock connector.
2 keys for safety lock.
CE22 power cord for mains connection (for 300W, 600W and 1200W models).
CE19 power cord for mains connection (for 2000W models).
Standards and regulations:
Low voltage directive: 2014/35/EU
EMC directive: 2014/30/EU
RoHS directive: 2011/65/EU
EN 61000-6-2:2005 + AC (2005)
EN 61000-6-4:2007 + A1 (2011)
EN 61326-1:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61010-1:2010
EUROLAB EMC decision n°11: issue 1 of 18 of December 2007
(*) for fixed polarity

Applications

Range

OUTPUT
VOLTAGE
(kV)
20 kV
30 kV
40 kV
50 kV
60 kV
80 kV
100 kV
120 kV
150 kV
300 W
Max current (mA)
Model
15
SR20KV-300W
10
SR30KV-300W
7.5
SR40KV-300W
6
SR50KV-300W
5
SR60KV-300W
3.75
SR80KV-300W
3
SR100KV-300W
Contact us
Contact us
Contact us
Contact us
600 W
Max current (mA)
Model
30
SR20KV-600W
20
SR30KV-600W
15
SR40KV-600W
12
SR50KV-600W
10
SR60KV-600W
7.5
SR80KV-600W
6
SR100KV-600W
Contact us
Contact us
Contact us
Contact us
1200 W
Max current (mA)
Model
60
SR20KV-1.2KW
40
SR30KV-1.2KW
30
SR40KV-1.2KW
24
SR50KV-1.2KW
20
SR60KV-1.2KW
15
SR80KV-1.2KW
12
SR100KV-1.2KW
Contact us
Contact us
Contact us
Contact us
2000 W
Max current (mA)
Model
10
SR20KV-2KW
70
SR30KV-2KW
50
SR40KV-2KW
40
SR50KV-2KW
30
SR60KV-2KW
25
SR80KV-2KW
20
SR100KV-2KW
Contact us
Contact us
Contact us
Contact us
You need