Format:
					19” Rack or 19” cabinet
				 
		
				
					Efficiency:
					> 90% at full load
				 
		
				
					Main Power Input:
					400 VAC ±10% 47-63 Hz
3 Phase + Earth
				 
		
				
					Input Power Factor:
					≥ 0.90
				 
		
				
					Inrush current:
					Limited to operating current at full power
				 
		
				
					Local controls:
					Mains power switch, safety lock, HV on, HV off, Over current mode, Preset, Voltage an current setting, Limitation of voltage setting.
				 
		
				
					Status Indicators:
					HV on, HV off, Line, Fault, Interlock, Remote, Over current limitation/protection, Regulation mode
				 
		
				
					Voltage and current display:
					4.5 Digit
				 
		
				
					Output voltage and current setting:
					Continuously adjustable from 0 to 100%
				 
		
				
					Local control mode:
					10 turn potentiometer (0.05% resolution)
				 
		
				
					Remote control mode:
					External 0 to 10V signal
				 
		
				
					Voltage and current regulation*:
					
				 
		
				
					Static Load regulation:
					±0.05% of full voltage or current for no load to full load variation – better on demand
				 
		
				
					Static Line regulation:
					±0.05% of full voltage or current for ±10% mains voltage variation (better on demand)
				 
		
				
					Stability (after 1-hour warm-up):
					100 ppm /hour, operating at constant load and temperature
				 
		
				
					Regulation modes:
					Constant Voltage (CV) and Constant Current (CC) regulations, with automatic crossover.
Power regulation on demand.
				 
		
				
					Protections:
					Short circuit, Arc quench, External interlock, Over temperature, Overload, Over voltage, Over current,
				 
		
				
					Cooling:
					Air forced
Air inlet on the front panel, with dust filters
Air outlet on the rear panel
				 
		
				
					Ambient temperature:
					From 0 to 50 °C
				 
		
				
					Ambient Humidity:
					0 to 80% at 25°C, 50% at 40°C (non-condensing)
				 
		
				
					Temperature coefficient:
					100 ppm/°C
				 
		
				
		
				
					Documentation:
					User manual, Test report, EU declaration of conformity (CE), RoHS2 declaration of conformity
				 
		
				
					Accessories:
					Removable 3 m coaxial HV cable with one plug mounted on one end.
Interlock connector.
2 keys for safety lock.
				 
		
				
					Standards and regulations:
					Low voltage directive: 2014/35/EU
EMC directive: 2014/30/EU
RoHS directive: 2011/65/EU
EN 61000-6-2:2005 + AC (2005)
EN 61000-6-4:2007 + A1 (2011)
EN 61326-1:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61010-1:2010
EUROLAB EMC decision n°11: issue 1 of 18 of December 2007
				 
		
				
					Usage in standard conditions
					Complete discharge
Max. frequency : 10 Hz
Capacitor Load
Reversal Voltage ≤10% of Vmax for a charging time between 0.1s and 5s